Server Sizing

Server Size and Specifications

To host Sentio SIEM, one of the main factors to take into account before selecting any server is the amount of events that the SIEM will hold.


The EPS depends on the size and type of the events that are being consumed (for example: syslog messages tend to be smaller than windows logs so we get a higher EPS).

vCPUs

RAM (GB)

EPS

Measurement Type

16

32

2,000

Extrapolated

32

64

4,000

Extrapolated

32

92

8,000

Based on real deployment

64

300

16,000

Based on real deployment


Storage requirements depend most heavily on your data retention needs. For a few months, a couple hundred GB are enough... but of course note that as you go higher in EPS and data retention the storage increases as well.


3rd Party Sizing

The below lists some useful links in sizing third party products which may be used with the SIEM such as Microsoft Windows Event Forwarding servers

Microsoft Windows Event Forwarding

WEC server requirements

While there is no clear guidance from Microsoft on this, here are some specifications to consider:

Minimum Specifications

OS Version

Windows Server 2019

CPU

8 cores

Memory (RAM)

16 GB

Dedicated Storage (logs)

100 GB

Max clients

500

Desirable Specifications:

OS Version

Windows Server 2022

CPU

16 or 32 cores

Memory (RAM)

32 GB

Dedicated Storage (logs)

200 GB

Max clients

1000

Source: https://support.aarnet.edu.au/hc/en-us/articles/7213530756879-WEC-Server